Introduction Of Flat Screen Printer Heating System

The Stenter setting machine presses the reset button on the operation panel, and the indicator is off

 The Stenter setting machine presses the reset button on the operation panel, and the indicator is off, and the start indicator flashes while the start indicator is pressed, the chain rotates, and the acceleration indicator flashes.

  1. In the stenter setting machine, click the icon of the circulation fan to enter the power setting window of the circulation fan, click the total button of the circulation fan to pop up a small window for setting the power of the circulation fan, click the number box on the white bottom to pop up a numeric keypad, and enter the required output power value , Press OK.
  2. In the stenter setting machine, click on the upper left or upper right corner of the exhaust fan icon to enter the exhaust fan power setting window, click the manual control button and confirm, click the white background number box to pop up a small numeric keyboard to enter the required value and confirm. If you click the automatic control button and confirm, the exhaust fan will automatically adjust the power of the exhaust fan.

To a certain extent, the stenter setting machine needs to click the digital box showing the temperature in the oven simulation icon to enter the heating window, click the heating total to set the heating temperature, or you can set the heating temperature of each oven separately. When the heating temperature is below 90 degrees, click the small fire icon to heat, and when the heating temperature is above 90 degrees, click the big fire icon to heat and confirm.

Correct the cloth threading route, pass the cloth feeding part and guide the cloth (from the cloth feeding frame to the operating table), and follow the correct cloth threading route to pass the cloth outlet guide belt (from the cloth overfeeding roller to the cloth outlet frame).

With the red stop button on the operation panel under Flat Screen Printer, the chain stops and the start indicator flashes. Pull the cloth guide onto the tentering chain and press the overfeeding wheel push button for about 10 seconds, and wait for the push button indicator to light up. Turn on the motors of each part of the cloth feeding mechanism to "1". Raise the pour chute, apply the pressure of the rolling car, turn on the motors of all parts of the operation table (except the needle protection entrance button), and click the cloth feed control button in the upper left corner of the cloth feed mechanism to green.